Feature:IPG Laser: Switch off Emission Enable during Jumps
Description:For USC1 and USC2:
If an IPG laser is connected, a mode will be introduced which allows to switch off Emission Enable (connected to OPTO_OUT_0) during jumps

Within SAMLight new parameters within the Settings-laser page will be introduced:

- flag: IPG Switch Off EmissionEnable during Jumps
- jump length - jumps longer than this value will lead to a switch off of EmissionEnable
- delay - when switching on EmissionEnable again, this delay is executed before to continue with the next vector
State:solved, bug fixed / feature implemented
Solved in version(s):REL_3_0_5_20110531_0663